6.5.1 SCSI-AdaptorBuild your own SCSI-Adaptor Kable
Use that adaptor to connect a ZIP device after the internal SCSI
Device of a C-LAB Machine. Do not connect anything to the external
SCSI2 Connector of your Falcon C-LAB Case. SCSI can't work with a Bus
in a 'Y' Form.
All SCSI Devices must be shown as one Line from Falcon to your
last SCSI Device. Do not connect anything in a 'Y' Junction to yor
Falcon!
Picture 1 - Wireing of a 50 to 25 SCSI Adaptor First
============================================================= * Do not connect unsigned pins to somewere * * Do not connect anyhing to open pins at your device * =============================================================
Picture 2 - SCSI2 to DB25 Adaptor
Picture 3 - Schematic of a 50 pin Flatcable
Here is the pinout of a 2.5" HD device. If you need to
connect a kind of that device outside of a notebook, so you can build
your own SCSI 2.5" to 50 Pin SCSI adaptor
Use this pinout to you own risk!
Copyright © Robert Schaffner (support@doitarchive.de) Letzte Aktualisierung am 23. Dezember 2003 |