[PageStream 2 document LYNX0001.DOC: 8.50 x 11.00 in, 1 objects] --- Page 1 --- Atari Technical Bulletin Number: LYNX-0001 Date: May 8, 1992 Page 1 of 1 Product(s) Affected: LYNX Model: LYNX I Type of ATB: As Needed ECO #: 1418, January 21, 1992 Reason for ATB: To correct premature failures of the internal power connector on the LYNX I. Notes: The power connector in the LYNX I needs to be replaced with the more reliable LYNX II power connector. Sub-assemblies affected are CA200552-001 REV A and CA200592-001, 002, 003, 004 REV K. Symptoms of Problem: Internal power connector fails to supply power to unit after prolonged use. Solution: 1. Replace power jack part number C101979-001 with power jack part number C101984-001.