[PageStream 2 document F0306.DOC: 8.50 x 11.00 in, 501 objects] --- Page 107 --- [56 drawing objects, see F0306.DOC.p107.svg] SECTION SIX DIAGNOSTIC FLOWCHARTS Start Connect Terminal To RS232 Port And Cycle Power No Display Readable? Yes No Display On Terminal? Error Message? No Yes Yes B No Diagnostic Error? Replace Parts Per Diagnostic Guide Run All Tests Yes C Replace Parts Per Diagnostic Guide Cycle Power Yes Error? No Restart Done No Other? Yes A --- Page 108 --- [36 drawing objects, see F0306.DOC.p108.svg] No Error on Diagnostic A Won't Load Disk? Yes Run Disk Diagnostic Or Replace Disk No Video Problem? Yes Trace Signal From Video Shifter To Output No Problem Found? No Run Appropriate Test Continuously Yes Contact ATARI Tech Support --- Page 109 --- [137 drawing objects, see F0306.DOC.p109.svg] No Display on Monitor or Terminal B No +5V Present? Yes Replace Power Supply No +5V Shorted To Ground? Replace Oscillator No 16 MHz Clock Present? Yes Yes Inspect Main PCB For Shorted +5V MC68030 Halted? Yes No No Found Short? Yes Replace COMBO Replace COMBO Or MC68030 No Replace Main PCB Remove Short And Recheck RS232 Display? Yes No See Theory Of Operation, Call Tech Support, Or Replace Main PCB Diagnostic Error? Yes No C Replace Parts Per Diagnostic Guide --- Page 110 --- [105 drawing objects, see F0306.DOC.p110.svg] No Display No Error C 16 MHz Clock Present No Replace The Crystal Yes Restart Ouput From VIDEL IC? No Replace VIDEL IC Yes Trace Output To Connector, Replace Failing Component OK? Yes Restart No Replace COMBO IC