Home Atari, Mac und PC seriell Modemkabel SCSI-Schnittstelle
 

12.7.3 Serial RS232 Port


Serial RS232 Port



Some people have problems after lighning and storm.
The first word is: Disconnect phone line and AC !

If your serial Port doasn't work after a thunderstorm, try to replace both serial line drivers (level fix) U13 abd U14. U5 / 1488 and U14 / 1489. They are normal parts. You can take it from any electonic store or from BEST-Electronics.

Serial Port J2 are a DB 9 Pin D-SUB connector.
All 9 Pin are wired thru T-Filters, L6, L8, L11, L12 and L7, L9 L10 and also L13 directly behind the port. First check all T-Filters with Ohmmeter, they all must have 0 Ohm


Note:

I changed all the "big" capacitors, and the 479 chip but it still didn't work. The ones I didn't check were on the solder side of the motherboard. I checked each one in the circuit until L45 did not get hot anymore. When I removed C9, L45 stayed cool. I repalced C9 and the serial works fine now. I don't know if the 479 was bad. I had to replace it because I cut it off the motherboard.



Abbildung 1 - 12V for RS232



So, the moral of the story is:
If L45 is very hot and serial does not work, check C9 first before fucking up your motherboard:)

Michael Grove


Pin 1 DCD
Serial Port Pin 1 -> L13 -> U14 / Pin 1

 
Pin 2 RxD
Serial Port Pin 2 -> L10 -> U14 / Pin 4
Receive Data

 
Pin 3 TxD
Serial Port Pin 3 -> L9 -> U5 / Pin 6
Transmit Data

 
Pin 4 DTR
Serial Port Pin 4 -> L7 -> U5 / Pin 8
Data Terminal Ready

 
Pin 5 GND
Serial Port Pin 5 -> GND Signal Ground / Shilding

 
Pin 6 DSR
Serial Port Pin 6 -> L12 -> U14 / Pin 10
Data Set Ready

 
Pin 7 RTS
Serial Por Pin 7 -> L11 -> U5 / Pin 3
Ready to Send

 
Pin 8 CTS
Serial Port Pin 8 -> L8 -> U14 / Pin 13
Clear To Send

 
Pin 9 RING
Serial Port Pin 9 -> L6 -> RING Wire
Message of an incoming Ring

 

Pin 14 of U5 are +12V DC! Pin 14 of U14 are +5V DC! All other Pin are directly connected to the SCC-Chip U13 / 85C30.

Pin 3 / U14 connected to Pin 24 / U13 (DCDB)
Pin 6 / U14 connected to Pin 31 / U13 (RXDB)
Pin 8 / U14 connected to Pin 33 / U13 (SYNCB)
Pin 11 / U14 connected to Pin 25 / U13 (CTSB)


Pin 12/13 of U5 are GND
Pin 9 / 10 of U5 are connected to Pin Pin 27 / U13 (DTR)
Pin 4 / 5 of U5 are connected to Pin Pin 29 / U13 (RxT)
Pin 2 of U5 is connected to Pin 26 / U13 (RTS)
Pin 1 of U5 is connected to C22 ( 0.1uF) and D2 (1N914)


Here you found the circuit diagram of an simple RS232 Circuit Tester
If you use DB ) seriall Connectors, use and 25 to 9 Adaptor
Green LED shows 'Low-Signal, a Red light shows a 'High-Level'




Abbildung 2 - Einfacher RS232 Tester






Abbildung 3 - Simple RS232 DB9 Tester




Hier finden Sie die Schaltung eines einfachen Testers für die serielle Schnittstelle an allen Atari-Computern. Wenn Sie DB9-Buchsen an ihrem Atari besitzen verweden Sie einen DB25 zu DB9 Adapter oder verschalten Sie die entsprechenden RS232 Pin nach dem Schema der DB9 Buchse und dem RS232 Tester. Sie brauchen eben nur die entsprechenden Pins analog zur 25 poligen Version zu verwenden

Ein grüne LED zeigt einen LOW-Pegel, die Rote einen 'High-Pegel' an.
Das ist zwar kein Allheilmittel, immerhin lassen sich aber so sehr schnell und einfach tote Verbindungen innerhalb der seriellen Schnittstelle feststellen Bleibt eine Leitung ständig High/Low oder ganz ohne Signal hat man einen Ansatzpunkt

Sie finden hier weiter oben eine Auflistung aller Pins der seriellen Schnittstelle des Atari Falcon F030 von der DB9 Stiftleiste über die T-Filter bis hin zum SCC-Chip U13. Sollen Sie nach einen Gewitter und Blitzschlag Probleme mit der seriellen Schnittstelle haben, ziehen Sie in Betracht die beiden Line Driver(Pegelwandler) 1488 und 1489 auszutauschen. Das sind handelsübliche Chips die es bei jedem Elektronikhänder gibt. Sollte das keine Auswirkung haben tauschen Sie auch den SCC U13 gegen genau den gleichen Typ 53C80 vom gleichen Hersteller. Der SCC aus einem Atari TT arbeitet hier nicht.

Viel mehr gibt es hier eigentlich nicht zu sagen. Es ist immer der gleiche dumme Fehler! Trennen Sie ihr Modem vor einem Gewitter vom Telefonanschluß!
Trennen Sie ihren Rechner vorher vom Stromnetz!




Abbildung 3 - RS232 wireing include 1488 / 1489






Abbildung 4 - RS232 wireing around SCC Chip








Copyright © Robert Schaffner (support@doitarchive.de)
Letzte Aktualisierung am 23. Dezember 2003